Website is intended for physicians
Search:
Всего найдено: 2

 

Abstract:

Aim: was to estimate long-term results of vertebral artery (VA) stenting in patients with vertebrobasilar insufficiency (VBI).

Material and methods: study included 194 patients with VBI caused by lesion of V1 segment of VA. All patients received the best course of drug therapy before admission to the clinic. In all these patients, atherosclerotic stenosis of 70% or more of VA was revealed in V1 sergment. All patients underwent surgical correction of V1 segment of VA. Open surgery was performed in «A» group – with a tortuosity of VA – 129(66,5%), in group «B» – without tortuosity of a VA – 65(33,5%) performed stenting of V1 segment of PA.

Bare-metal stents were implanted in 44 patients, drug-eluted stents - 14, renal stents – 7. Distal protection was used in 14 patients. In remaining patients, stenting was performed without embolic protection devices.

Main criteria for evaluating of results were: patency of the reconstruction zone and clinical improvement in the patient after surgery. Statistical processing of results was carried out by calculating ?2, the exact Fisher test (EFT) and constructing of Kaplan-Meier survival curves.

Results: it was determined that in «hopeless» patients, from the point of view of drug treatment, it is possible to achieve a significant clinical effect by surgical methods. Of 194 patients, clinical improvement in the early postoperative period was achieved in 189(97,4%) patients, after 1 year in 177 (91,2%) patients, and after 3 years in 156(80.2%) patients.

In case of stenting of V1 segment of VA – we received excellent immediate results – 100% of technical and clinical success. However, in the long term, results of open operations were better than results of stenting. 3 years after operation, a higher clinical efficacy of open methods was determined – 79,8%, in contrast to stenting – 73,8%. Although, differences were not statistically significant (p> 0,05). 3 years after operation, in case of open operations, a significantly smaller number of restenosis of the reconstruction zone was 1.6%, than with stenting – 15,4% (p <0.05). However, in patients with open operations, more thrombosis of the reconstruction zone were revealed – 5,5% than in patients with stenting – 1.5% (p>0,05). When performing open operations on V1 segment of VA, strokes were fewer – 2.3%, than in group of V1 stenting segment of VA – 3.1% (p> 0.05). When comparing Kaplan-Meyer curves, the median during open surgeries on VA is not achieved after 18 years, and in group of stenting of VA, it occurs after 7 years.

Conclusion: stenting of V1 segment of vertebral arteries in patients with VBI is not the operation of choice in terms of long-term results. However, this operation can be considered as the first stage of brain revascularization in the presence of significant stenosis of V1 segment of vertebral artery and low brain tolerance to ischemia in patients with multiple lesions of brachiocephalic arteries.

 

References

1.     Savitz SI, Caplan LR: Vertebrobasilar disease. N Engl J Med. 2005; 352:2618-2626.

2.     Caplan LR, Wityk RJ, Glass TA, Tapia J, Pazdera L, Chang HM, Teal P, Dashe JF, Chaves CJ, Breen JC, Vemmos K, Amarenco P, Tettenborn B, Leary M, Estol C, Dewitt LD, Pessin MS: New England Medical Center Posterior Circulation registry. Ann Neurol. 2004; 56:389-398.

3.     Vereschagin NV. Pathology of vertebrobasilar system and cerebrovascular accidents. M. 1980; 312. [In Russ].

4.     Puzin MN, Zinoveva GA, МеtelkinaLP. Aspects of medical treatment of patients with vertebrobasilar insufficiency. Klinicheskaya farmakologiya i terapia, 2006; 2: 23-26. [In Russ].

5.     Berguer R, Morasch M, Kline R. A review of 100 consecutive reconstructions of the distal vertebral artery for embolic and hemodynamic disease. J Vasc Surg. 1998; 27 (5): 852-859.

6.     Pokrovskii AV, Belojarcev DF. Long-term results of operations subclavian-carotid transposition. Angiologiya i sosudistaya khirurgiya 2002; 8 (2): 84 - 91. [In Russ].

7.     He Y, Bai W, Li T et al. Perioperative complications of recanalization and stenting for symptomatic nonacute vertebrobasilar arteryocclusion. Ann Vasc Surg. 2014 Feb; 28 (2):386-393.

8.     2017 ESC Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery (ESVS): Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries Endorsed by: the European Stroke Organization (ESO)The Task Force for the Diagnosis and Treatment of Peripheral Arterial Diseases of the European Society of Cardiology (ESC) and of the European Society for Vascular Surgery (ESVS). Eur Heart J. 2018 Mar 1; 39(9): 763-816.

9.     National guidelines on the management of patients with brachiocephalic artery disease. Angiologiya i sosudistaya khirurgiya. 2013; 19 (2), appendix: 70 [In Russ].

10.   Schonewille WJ, Algra A, Serena J, Molina CA, Kappelle LJ. Outcome in patients with basilar artery occlusiontreated conventionally. J Neurol Neurosurg Psychiatry. 2005; 76:1238-1241.

11.   Coward LJ, McCabe DJ, Ederle J, Featherstone RL, Clifton A, Brown MM: Long-term outcome after angioplasty and stenting for symptomatic vertebral artery stenosis compared with medical treatment in the Carotid And Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomized trial. Stroke. 2007; 38:1526-1530.

12.   Compter A, van der Worp HB, Schonewille WJ, Vos JA, Algra A, Lo TH, Mali WPThM, Moll FL and Kappelle LJ. VAST: Vertebral Artery Stenting Trial. Protocol for a randomized safety and feasibility trial. Trials 2008; 9: 65.

13.   Clifton A, Markus H, Kuker W, Rothwell P.E-050. The Rationale for the Vertebral artery Ischaemia Stenting trial (VIST): NeuroIntervent Surg 2013; 5. Suppl 2 A56.

14.   Compter A et al. VAST investigators. Stenting versus medical treatment in patients with symptomatic vertebral artery stenosis: a randomised open-label phase 2 trial. Lancet Neurol. 2015 Jun; 14(6): 606-614.

15.   VIST (Vertebral artery Ischaemia Stenting Trial) ISRCT N 95212240.

16.   Markus HS, Harshfield EL, Compter A. et al. Stenting for symptomatic vertebral artery stenosis: a preplanned pooled individual patient data analysis. Lancet Neurol. 2019 Jul; 18(7): 666-673.

https://doi.org/10.1016/S1474-4422(19)30149-8

17.   Markus HS, Larsson SC, Dennis J et al. Vertebral artery stenting to prevent recurrent stroke in symptomatic vertebral artery stenosis: the VIST RCT. Health Technol Assess. 2019 Aug; 23(41): 1-30.

 

Abstract

Introduction: article presents the first experience and long-term results of using domestic coronary balloon-expandable stents with a bioinert carbon coating, «Nanomed».

Aim: was to evaluate long-term results of using domestic coronary balloon-expandable stents with bioinert linear chain carbon coating (BLCCC), «Nanomed».

Materials and methods: the study included 387 patients, suffering from coronary heart disease, who underwent endovascular myocardial revascularization from 2016 to 2018, with implantation of coronary balloon-expandable stents with BLCCC by the Nanomed company, Penza. The control group included 320 patients who underwent endovascular myocardial revascularization with implantation of coronary balloon-expandable cobalt-chromium stents «MSure Cr» of the company «Multimedics», during the same period. A comparative estimation of long-term results was carried out on the basis of a study of the overall frequency of repeated myocardial revascularization; repeated interventions on the target vessel; the frequency of interventions on other coronary arteries with the progression of atherosclerosis; long-term survival rates.

Results: in the long-term period, the overall probability of absence of repeated revascularization in 47 months after PCI was 78,3 ± 2.1% and 72,1 ± 2.4% in the «Nanomed» BLCCC and «MSure Cr» groups, respectively. There was no statistically significant difference between groups (Log. Rank=0,77). However, the incidence of restenosis in the stent was statistically significantly higher in the «MSureCr» group. (p = 0,027). The overall probability of survival in 47 months after surgery was 98,2±2,4% and 98,1±2.6% in groups 1 and 2, respectively. No statistically significant difference between groups was found (Log. Rank=0,4).

Conclusions: 1. The use of a coronary balloon-expandable stent with a BLCCC, Nanomed for endovascular myocardial revascularization is an effective treatment in patients with coronary heart disease.

2. Long-term results of using bioinert carbon-coated stents, Nanomed and MSureCr stents were comparable in terms of absence of myocardial re-revascularization procedures due to relapse of the angina pectoris and survival time of up to 47 months. However, the incidence of restenosis in a stent with a bioinert carbon coating, Nanomed was statistically significantly lower.

 

References

1.     Allender S, Scarborough P, O’Flaherty M, Capewell S. Patterns of coronary heart disease mortality over the 20th century in England and Wales: Possible plateaus in the rate of decline. BMC Public Health 2008, 8, 148.

2.     De Scheerder I, Wang K, Wilczek K et al. Experimental study of thrombogenicity and foreign body reaction induced by heparin-coated coronary stents. Circulation. 1997; 95: 1549-1553.

3.     Morice M, Urban P, Greene S, Schuler G, Chevalier B. Why are we still using Coronary Bare-Metal Stents? JACC 2013;61;1122-3.

4.     De Mel A, Cousins BG, Seifalian AM. Surface modification of biomaterials: A quest for blood compatibility. Int. J. Biomater. 2012;  707863:1-707863:8.

5.     Kochkina K, Protopopov A. Comparative results of the use of stents with drug and carbon coatings in treatment of patients with all forms of acute coronary syndrome in the long-term follow-up. Kompleksnye problemy serdechno-sosudistyh zabolevanij. 2014; 1:52-58 [In Russ].

6.     Carrie D, Lefevre T, Cherradi R, et al. Does Carbofilm coating affect in-stent intimal proliferation? A randomized trial comparing Rx multi-link penta and TecnicCarbostent Stents: SIROCCO Trial. J Interv Cardiol. 2007; 20(5):3818.

7.     De Mel A, Jell G, Stevens MM, Seifalian AM. Biofunctionalization of biomaterials for accelerated in situ endothelialization: A review. Biomacromolecules. 2008; 9: 2969-2979.

8.     Hofma SH, Whelan DM, van Beusekom HM, Verdouw PD, van der Giessen WJ. Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model. Eur. Heart J. 1998; 19: 601-609.

9.     Wu KK, Thiagarajan, P. Role of endothelium in thrombosis and hemostasis. Annu. Rev. Med. 1996, 47, 315-331.

10.   Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. J. Am. Coll. Cardiol. 2006; 193-202.

11.   Farb A, et al., Pathology of acute and chronic coronary stenting in humans. Circulation. 1999; 99(1): 44-52.

12.   Sarno G, et al., Lower risk of stent thrombosis and restenosis with unrestricted use of 'newgeneration' drug-eluting stents: a report from the nation wide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eur Heart J. 2012;  33(5): 606-13.

13.   Palmerini T, et al., Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis. Lancet. 2012;  379(9824): 1393-402.

14.   Antoniucci D, Bartorelli A, Vaenti R, et al. Clinical and angiographic outcome after coronary artery stenting with the Carbostent. Am J Cardiol. 2000; 85: 821-825.

15.   Antoniucci D, Valenti R, Migliorini A, et al. Clinical and angiographic outcomes following elective implantation of the Carbostent in patients at high risk of restenosis and target vessel failure. CathetCardiovasc Interv. 2001; 54: 420-426.

16.   Gian B Danzi, Cinzia Capuano, Marco Sesana et al. Six-Month Clinical and Angiographic Outcomes of the Technic Carbostent(TM) Coronary System: The Phantom IV Study. J Invasive Cardiol. 2004; 16(11): 641-4.

17.   Wiemer M, Butz T, Schmidt W, Schmitz KP, Horstkotte D, Langer C. Scanning electron microscopic analysis of different drug eluting stents after failed implantation: From nearly undamaged to major damaged polymers. Catheter. Cardiovasc. Interv. Off. J. Soc. Cardiac. Angiogr. Interv. 2010; 75: 905-911.

18.   Pendyala L, Jabara R, Robinson K, Chronos N. Passive and active polymer coatings for intracoronary stents: Novel devices to promote arterial healing. J. Interv. Cardiol. 2009; 22: 37-48.

19.   Kesavan S, Strange J, Johnson T et al. First-in-man evaluation of the MOMO cobalt-chromium carbon-coated stent. EuroIntervention 2013; 8:1012-1018.

20.   Jung JH, Min PK, Kin JY, Park S, Choi EY, Ko YG, Choi D, Jang Y, Shim WH and Cho SY: Does a carbon ion-implanted surface reduce the restenosis rate of coronary stents? Cardiology. 2005; 104 (2): 72-75,

21.   Kim Y, Whan Lee C, Hong M et al. Randomized comparison of carbon ion-implanted stent versus bare metal stent in coronary artery disease: The Asian Pacific Multicenter Arthos Stent Study (PASS) trial. American Heart Journal. 2005; 149 (2).

22.   George Cesar Ximenes Meireles, Luciano Mauricio de Abreu, Antonio Artur da Cruz Forte et al . Randomized comparative study of diamond-like carbon coated stainless steel stent versus uncoated stent implantation in patients with coronary artery disease. Cardiol. Sro Paulo Apr. 2007; 88 (4).

23.   Ben-Dor I, Waksman R, Pichard A.et al. The Current Role of Bare-Metal Stents. Cardiac interv. 2011; 1:40-45.

24.   Snoep JD, Hovens MM, Eikenboom JC, van der Bom JG, Jukema JW, Huisman MV. Clopidogrel nonresponsiveness in patients undergoing percutaneous coronary intervention with stenting: a systematic review and metaanalysis. Am Heart J. 2007; 154:221-31.

25.   Bartorelli A, Trabattoni D, Montorsi P Aspirin alone antiplatelet regimen after intracoronary placement of the Carbostent: the ANTARES study. Catheter Cardiovasc Interv. 2002 Feb; 55(2):150-6.

26.   Goods C, Al-Shaibi, Liu M et al. Comparison of aspirin alone versus aspirin plus ticlopidin after coronary artery stenting. Am J Cardiol. 1996; 78:1042-1044.

27.   Leon M, Baim D,Popma J et al. A clinical trial comparing three anthitrombotic drug regimens after coronary artery stentings. Stent Anticoagulation Restenosis Study Investigators. N Engl J Med. 1998; 339:1665-1671.

28.   Braun P et al. Prospective randomized study of the restenotic process in small coronary arteries using a Carbofilm coated stent in comparison with plain old balloon angioplasty: a multicenter study. Catheter Cardiovasc Interv. 2007 Dec 1; 70(7):920-7.

29.   Taema K, Moharram A. Long Term Clinical Follow-up of Carbon Coated Stents: Comparative Study with Bare-Metal Stents Med. J. Cairo Univ. 1-8, March: 18, 2014; 82 (2). 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы